| Nominal wattage | 50.00 W |
| Nominal output power | 50 W 1) |
| Nominal voltage | 120…277 V |
| Nominal output voltage | 20…55 V |
| Input voltage AC | 108…305 V 2) |
| U-OUT (working voltage) | 60 V |
| Nominal current | 0.26 A 3) |
| Nominal output current | 600…1250 mA |
| Inrush current | 30 A 4) |
| Output current tolerance | ±5 % 5) |
| Output ripple current (100 Hz) | 30 % |
| Mains frequency | 50/60 Hz |
| Total harmonic distortion | 15 % 6) |
| Power factor λ | 0.95 7) |
| ECG efficiency | 86 % 8) |
| Device power loss | 9.6 W 9) |
| Max. ECG no. on circuit breaker 10 A (B) | 11 10) |
| Max. ECG no. on circuit breaker 16 A (B) | 17 10) |
| Max. ECG no. on circuit breaker 25 A (B) | 28 10) |
| Surge capability (L/N-Ground) | 6 kV 11) |
| Surge capability (L-N) | 6 kV 12) |
| Galvanic isolation | SELV |
| Flickering metric (Pst LM) | ≤1 |
1) Partial load 12…50 W / Not dimmed
2) Permitted voltage range
3) 0.50 A for 120 VAC / At 230 V
4) twidth = 250 µs (measured at 50 % Ipeak)
5) Within nominal output current range
6) Max. output power at 230 VAC
7) Minimum/Full load at 230 V/Half load at 230 V
8) At full load, default current and 230 V
9) Maximum
10) Type B
11) EQUI @ 12 Ohm acc. to EN 61547
12) @ 2 Ohm, acc. to EN61547
| Flickering metric (Pst LM) | ≤1 |
| Stroboscope effect metric (SVM) | ≤0.4 |
| Length | 168.00 mm |
| Mounting hole spacing, length | 152,0 mm |
| Width | 50.00 mm |
| Height | 30.00 mm |
| Wire preparation length, input side | 10 mm |
| Wire preparation length, output side | 10 mm |
| Product weight | 490.00 g |
| Casing material | Metal |
| Body material | Metal |
| Ambient temperature range | -40…+55 °C 1) |
| Maximum temperature at tc test point | 80 °C 2) |
| Max.housing temperature in case of fault | 120 °C |
| Permitted rel. humidity during operation | 5…85 % 3) |
1) Ta(max)
2) Maximum at the Tc-point
3) Non condensing, absolute humidity: 36g/m³
| ECG lifetime | 80000 h 1) |
1) At Tcase = 70°C at Tc point / 10% failure rate
| Encapsulated | Yes |
| Product remark | No on/off switching of lamps possible via 0...10 V interface |
| Dimmable | Yes |
| Dimming interface | 2DIM, 1…10 V, AstroDIM |
| Dimming range | 30…100 % |
| Overheating protection | Yes |
| Overload protection | Automatic reversible |
| Short-circuit protection | Yes |
| No-load proof | Yes |
| Max. cable length to lamp/LED module | 10 m |
| Suitable for fixtures with prot. class | I, II |
| Type of connection, output side | Wires |
| Approval marks – approval | CE, ENEC 15, UR, CQC |
| Standards | Acc. to EN 61347-1, Acc. to EN 61347-2-13, Acc. to EN 62384, Acc. to EN 55015:2006 + A1:2007 + A2:2009, Acc. to EN 61547, Acc. to FCC 47 part 15 class A, Acc. to IEC 61000-3-2, Acc. to IEC 61000-3-3, UL-8750 |
| Protection class | I/II |
| Type of protection | IP64 |
| Temperature range at storage | -25…80 °C |
| Quantity of precious metals | 0 mg |
| Quantity of rare earths | 0 mg |
| Minimum rate of recycled material in packaging | 80 % 1) |
| Minimum percentage of recycled content in the product | 0 % 1) |
| Product recyclability | Mostly recyclable product 1) |
| Packaging recyclability | Mostly recyclable packaging 1) |
| List of dangerous substances contained in the product in concentrations greater than 0.1% in mass percentage | No |
| Contains substances of very high concern in concentrations greater than 0.1% by mass percentage | Yes |
| List of substances of very high concern in concentrations greater than 0.1% in mass percentage | Lead (7439-92-1) |
1) According to AGEC Decree 2022-748 (French Anti-Waste-Legislation for a Circular Economy)
| Product code | Packaging unit (Pieces/Unit) | Dimensions (length x width x height) | Gross weight | Volume |
|---|---|---|---|---|
| 4052899173804 | Unpacked 1 |
490.00 g | ||
| 4052899173811 | Shipping box 20 |
368 mm x 338 mm x 85 mm | 10492.00 g | 10.57 dm³ |
| EAN | EFO number | ELDAS number |
|---|---|---|
| 4052899173804 | 6608506 | 919391040 |